Browse all practice questions for the LADWP Electric Station Operator – Circuit Breakers, Disconnects, Transformers Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

LADWP Electric Station Operator – Circuit Breakers, Disconnects, Transformers Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Station ______ transformers are the distribution transformers for substations, providing single-phase power for lighting and three-phase power for equipment.
  • In an ideal transformer with a turns ratio of 2:1 (Np:Ns), the secondary voltage is what fraction of the primary voltage under ideal conditions?
  • A great variety of operating conditions can be easily reproduced on the ______.
  • Which factor primarily limits the current-carrying capacity of transformers at elevated temperatures?
  • When operating at voltages above 1000 V, which tool rules apply for contacting live parts?
  • Which statement best describes impedance grounding in electrical systems?
  • The ability of a substance to resist electrical current flow is described as its Dielectric strength.
  • Which of the following is a common cause of transformer overheating in operation?
  • In distribution stations, load transfer to a paralleled bank is achieved by opening the bank __________ side CB.
  • The electrical function of switches falls into two categories: ___________ of relatively high values of current and voltage under load and the switching of circuits to provide a visual confirmation of de-energization.
  • What is differential protection and what does it monitor?
  • What voltages are typical for the DWP Transmission System?
  • Which component's surface is involved in porcelain fragmentation due to fault currents?
  • Large-bank energization requires attention because magnetizing current can affect what aspect of service?
  • This is the insulating mechanism that occupies the space between the open contacts of a CB and prevents the flow of current through the device while the contacts are in the open position.
  • ______ transformers are used to step voltage down to a safe value, typically 120 volts.
  • A transformer whose secondary or output voltage is lower that its input or primary voltage is called a step-________ transformer.
  • If ______ currents are allowed to flow unchecked, they would cause widespread outages by destroying electrical equipment.
  • A certain amount of current flows when a bank is first energized. This current is known as __________ current.
  • A special type of transformer is the ______ transformer, used for measurement of electrical quantities and for control purposes.
  • What not only helps extend the life of transformers but also increases its current carrying capacity?
  • ______ transformers are used to step down current to a safe value, a maximum of 5 amps.
  • The amount of __________ delivered by the secondary winding is less than the amount supplied to the primary winding.
  • Why is the transformer vector group important for protection coordination?
  • __________ switching performed by Operators is usually in response to power outages and abnormal conditions such as overloads.
  • The placement of ___________ electrical switches in the power system makes it possible to limit both the duration and the extent of power outages.
  • The outages that are short-term and limited are intended to isolate circuits to clear a ______.
  • When current flow in a coil causes an emf to be induced in itself, it is known as ______.
  • The mechanical indicator used at the CB to indicate the status of the breaker is called the __________.
  • The current that continues to flow across the opening contacts of a switch (or across any opening in a circuit) is known as an ______.
  • Electrical current may flow across the contacts of how many electrical switches before it reaches the consumer?
  • What is a Buchholz relay and what fault does it detect?
  • In station designs, circuits are placed in what configuration with disconnects?
  • Why is visual disconnection important for repair and maintenance crews?
  • Which of the following is not listed as a benefit of placing automatic switches in the power system?
  • The losses due to hysteresis and eddy currents in the magnetic core are known as what?
  • Automatic switches placed in the power system provide reliability, flexibility, and safeguards. Which term best describes the third benefit?
  • What does the transformer vector group Dyn11 indicate about winding connections and phase displacement?
  • What is an impedance relay and what does it protect?
  • Which statement describes definite-time overcurrent protection as opposed to inverse-time protection?
  • What is the vector group of a transformer, and why is it important for connections?
  • Disconnects through which current does not normally flow usually remain _________.
  • Which gas is listed among dielectric media used in circuit breakers for interrupting power system currents?
  • Good operators plan ahead by preparing __________ plans.
  • Which component in a circuit breaker is typically associated with porcelain construction?
  • A switching plan must include the name of the __________ being operated and the major steps required to perform the switching.
  • Which device is used to energize or de-energize transformers and voltage regulators?
  • If the source impedance increases, what happens to the short-circuit current at the bus?
  • What is the per-unit system primarily used for in protection and relay coordination?
  • Dry, clean air normally has a ______ strength of about 10,000 volts per inch. This means that you would have to apply a voltage greater than 10,000 volts across conductors separated by one inch of air to establish current flow across the separated conductors.
  • A simple power transformer essentially consists of two ______.
  • Circulating currents that cause unwanted heating in a transformer are called what?
  • Which statement correctly differentiates a fused disconnect from a non-fused disconnect?
  • Which component connects generators to the DWP Transmission System and typically steps up voltage from 18 kV to transmission levels of 138 kV or 230 kV?
  • ______ switching is performed in substations to provide adequate capacity for customer load, provide an alternate source for customer load when equipment maintenance is required, and to search for 4.8kV grounds.
  • The ability of a substance to prevent the flow of electrical current is described as its __________ strength.
  • Instrument transformers are used for measurement of electrical quantities and for control purposes. Which statement best describes their use?
  • Which device provides energy transfer between isolated circuits using magnetic coupling?
  • Which method helps cool the arc by using multiple contacts and fast opening times?
  • Which statement distinguishes a three-phase fault from a single-line-to-ground fault in terms of current path?
  • The current that flows across the gap in air when contacts separate is called the ______.
  • Air has a high ______ value so this current flow creates heat.
  • Before closing a breaker to re-energize a line, which checks should be verified?
  • What is tested in a turn ratio test for a transformer, and what indicates a correct result?
  • Large three-phase power transformers are generally referred to as what?
  • What does the presence of gas in transformer oil typically indicate?
  • If a transformer has primary 80 turns and secondary 40 turns, the turns ratio is.
  • Short-term, limited outages are intentionally caused to isolate circuits to clear a ______.
  • Well-designed transformers are typically about what percent efficient?
  • What is the primary purpose of a circuit breaker in a power system?
  • In an ideal transformer, if Vs > Vp, the secondary current Is compared to the primary current Ip: it decreases.
  • Which protection scheme is designed to trip all three phases together for a three-phase fault?
  • In distribution stations, load is transferred to a paralleled bank by normally opening the bank __________ side CB or CBs.
  • In distribution stations, what equipment steps down 34.5 kV to 4.8 kV?
  • Which dielectric medium used in circuit breakers is described as vacuum chambers?
  • Dirt contamination can reduce the interrupting capabilities by reducing the dielectric strength when moisture is present. Which statement best reflects this effect?
  • What does transformer impedance percentage indicate for fault levels?
  • The rapid fragmentation of porcelain when a fault current travels along an insulator surface is known as a porcelain ______.
  • What is the function of a differential relay in a transformer bank?
  • Which device may share winding and potentially have no isolation between circuits?
  • Which current flows when a bank is first energized, not during steady-state operation?
  • The mechanical linkage in a circuit breaker is often described as what component, also referred to as the actuating arm or lever?
  • Localized areas of greater heat are called __________?
  • Which device is used to perform switching operations on high voltage circuits to control power delivery?
  • When outages occur, operators re-route current flow to circuits that are not ______.
  • The losses due to resistance of the windings are called what?
  • Why is it important to coordinate breaker trip settings with the protection philosophy?
  • How does a fused disconnect differ from a non-fused disconnect?
  • Which transformer type provides galvanic isolation between primary and secondary windings?
  • An ideal __________ is one in which all the lines of force produced by the primary winding inductively link every turn of the secondary winding.
  • In substation switching procedures, what is the purpose of issuing a permit before performing switching?
  • One of the primary tasks of the Electric Station Operator is to perform which operation on high voltage circuits?
  • Which type of transformer is used to step down current to a safe value, a maximum of 5 amps?
  • Which statement best describes the core material used in transformers?
  • What is ground fault protection and where is it typically applied?
  • When there is no physical or electrical connection between the two coils yet energy is transferred from one coil to the other. The coils are said to be ______ coupled.
  • ________ must never be used to interrupt current flow in circuit.
  • The primary voltage of distribution transformers is typically what value?
  • What device allows the transfer of electric energy between two circuits that are completely insulated from each other through magnetic induction?
  • In a transformer, adding more turns to the winding primarily increases which parameter related to magnetic linkage?
  • Alternating current is easier to interrupt than direct current because periodically (120 times per second in a 60Hz circuit) the current value becomes ______.
  • What equipment is typically used to implement ground fault protection on feeders and buses?
  • Which banks connect together buses of different voltages such as 138 kV and 230 kV?
  • Core losses in a transformer are composed of which two types of losses?
  • What is the operating principle of an SF6 gas circuit breaker?
  • ______ stations banks are configured with either one or two 4.8kV (low side) circuit breakers (CBs).
  • Disconnects, through which current normally flows, must remain ______ at all times.
  • The heat loss due to the friction of molecules during magnetization is called what?
  • In a 60 Hz circuit, how many times per second does the current cross zero?
  • Which statement about transformer protection and vector groups is accurate?
  • How does a tap changer affect voltage regulation under varying load?
  • A ________-shaped coil allows a much stronger field to be created than a flat coil does.
  • Laminating the core with thin sheets of silicon steel reduces which type of loss?
  • What are standard practices for lockout/tagout (LOTO) when working on electric equipment?
  • What term describes the second category of switch function described alongside manipulation?
  • Which property of silicon steel contributes to its suitability for transformer cores?
  • The energy transfer between windings without direct electrical connection relies on what type of coupling?
  • Station service transformers provide single-phase power for lighting and three-phase power for equipment. Which statement best describes their output?
  • Electrical ________ are installed in the path from the generator to the consumer to provide reliability, flexibility, and safeguards for the electrical power system.
  • ________ switching operations include automatic reclosers (ARs), Voltage Pickup Unit (VPUs), and Automatic Transfer Switching (ATSs).
  • Which statement correctly describes the insulation media and typical applications of oil-filled and dry-type transformers?
  • The ________ operation of these electrical switches can pose a serious hazard to personnel, cause destruction of equipment, and cause unnecessary interruptions.
  • Bank-in-Service caps are __________ devices that are applied to the control handles of closed bank CBs.
  • What are the typical steps in a substation switching procedure after de-energizing?
  • After a fault, what action helps restore electrical service?
  • Operators use electrical switches to perform routine, automatic, and ______ switching operations on the electrical system.
  • Transformer ratios of 400:1 are typically used in ______ transformers, depending on installation and equipment needs.
  • Severe contamination of a dielectric medium can cause circuit breakers to __________ by allowing an arc to be sustained between the open contacts or the contacts and the grounded tank.
  • The operating time, from fully open to fully closed, in many large CBs, is often less than __________ seconds?
  • Which type of transformer is used to step voltage down to a safe value, typically 120 volts?
  • What is the Department's Subtransmission System voltage?
  • Some of the materials used in __________ that have sufficient dielectric strength to interrupt power system currents include insulating oils, pressurized inert gases, sulfur hexafluoride gas, and vacuum chambers?
  • What is the function of a sectionalizer in a distribution network?
  • In an ideal transformer with a turns ratio of 1:2 (Np:Ns), the secondary voltage is what fraction of the primary voltage under ideal conditions?
  • ________ switching is for maintenance, construction, cleaning, testing, etc.
  • Proper procedure requires banks to always be energized from the __________ side.
  • What is breaker-failure protection?
  • During abnormal conditions, current often exceeds the normal limitation of these devices by as much as _____ to _____ times their normal rating.
  • What is the role of current transformers (CTs) in protection circuits?
  • If the base apparent power Sbase is doubled while the voltage base remains the same and Zactual unchanged, how does Zpu change?
  • Disconnects are used to energize or de-energize short sections of conductor such as leads connecting a circuit breaker to its associated disconnects. Which term describes the portion connected to the circuit breaker?
  • Which contaminant, especially when moisture is present, can destroy the interrupting capabilities of a dielectric medium?
  • Name two common transformer cooling methods and where they are used.
  • Differentiate solidly grounded neutral and impedance-grounded neutral.
  • In a transformer, what happens to current when the voltage steps down?
  • __________-ratio is the number of turns of wire in the primary winding compared to the number of turns in the secondary winding.
  • The secondary voltage of distribution transformers is typically which of the following?
  • What is the primary purpose of a sectionalizer in a distribution network?
  • Which banks are dedicated to individual lines?
  • What does "breaking capacity" of a circuit breaker mean?
  • High temperature limits the what carrying capacity of transformers?
  • What is a relay coordination study and its purpose?
  • Which statement best describes how LV line currents relate to HV line currents in a delta-wye transformer?
  • What is the primary role of distribution transformers?
  • Which combination of PPE is typically required for arc flash protection?
  • Larger transformers are about _____% efficient.
  • The act of connecting two circuits together so that current can simultaneously flow through both of them is known as __________.
  • How do you verify proper phase rotation when connecting a transformer bank?
  • What does the presence of gas in transformer oil indicate?
  • The heat from a fault current path across the surface of a bushing or insulator causes porcelain to ______.
  • Small and medium sized __________ are self-cooled; that is, cooling takes place by direct radiation from the tank to the surrounding air.
  • During switching a line, what is the recommended sequence for opening devices?
  • What is the importance of proper working clearance around energized equipment?
  • In per-unit impedance calculations, which expression correctly gives Isc (per unit) in terms of the base values?
  • __________ are not designed to interrupt current flow, open or close circuits, or energize and de-energize circuits other than short sections.
  • Which currents, if allowed to flow uncontrolled, would quickly cause widespread outages by destroying electrical equipment?
  • Transformer ratios of 400:1 are typically used in instrument transformers. Which type of transformer is described?
  • A measure of the ability of a substance to conduct magnetic lines of force is called ______.
  • In a transformer, what quantity is stepped down when voltage is stepped up?
  • How does a delta-wye transformer affect line currents and phase angles?
  • Why is arc-flash safety critical when operating high-voltage equipment?
  • What type of electrical component has no dielectric strength and allows current to flow in a circuit?
  • A circuit that is not affected by a fault is described as ______.
  • Improper operation of electrical switches can pose what type of risk?
  • ________ are usually operated manually by the use of levers, cranks, and "hook-sticks poles."
  • Which dielectric medium has a relatively high dielectric strength and is used in many low voltage applications such as home light switches?
  • What is the purpose of a transformer bushing test?
  • What property of air determines its ability to withstand high voltages before breakdown between conductors?
  • Which action best describes restoring service after a fault by using alternate paths?
  • In LADWP practice, what is the difference between a circuit breaker and a disconnect switch?
  • In an ideal transformer with Np:Ns = 3:1, the secondary voltage is what fraction of the primary voltage?
  • A megger test on transformer windings is typically used to assess what?
  • Transformer oil in good condition must withstand _____kV applied across two flat electrodes submerged in a sample of the oil without arcing.
  • Much stronger ________ fields are obtained if the wire is wound into a coil with many turns of wire.
  • Bank-in-Service caps are applied to closed bank CBs as blocking devices; what term describes this function?
  • Failure of the mechanical __________ (sometimes referred to as the actuating arm or lever) can cause serious damage to the circuit breaker or may energize normally non-energized portions.
  • Visual disconnection is usually necessary to create __________ working conditions for repair and maintenance crews.
  • What is the term for the phenomenon where a changing current in one coil induces current in a nearby coil without a direct connection?
  • Which instrument is used to measure insulation resistance in transformers during testing?
  • The heat caused by iron and copper losses shortens the service life of what materials used in transformer windings?
  • Disconnects that do not normally carry current are typically kept in which state to prevent unintended energization?
  • Which type of steel, known for high permeability, is used for manufacturing transformer cores?
  • Which devices are used to manipulate high values of current and voltage in circuits that are carrying current or will be carrying current following the operation?
  • What does Zbase represent in per-unit calculations?
  • If a transformer has higher impedance, what is the expected effect on fault current?
  • If a second coil is placed in the field of the first coil that is connected to an AC source, the rising and collapsing magnetic field of the first coil will cut across the second coil and will induce an AC voltage in the second coil as well. This is known as ______ induction.
  • How is symmetrical short-circuit current at a bus typically calculated?
  • Distribution transformers can be configured as which of the following options?
  • What is the purpose of a neutral grounding resistor (NGR) in an impedance-grounded system?
  • Using multiple contacts and rapid opening times helps ______ the arc by reducing the cross sectional area of the arc or by lengthening it.
  • Breaker-failure protection serves to protect the system by which means?
  • What is a bus-tie breaker and where is it used?
  • Back emf or counter emf is also referred to as what kind of voltage?
  • How does inverse-time overcurrent protection differ from definite-time overcurrent protection?
  • What is the purpose of a reclosing scheme in transmission protection?
  • ________ switching operations include insolate trouble, restoration, 4.8kV Ground Search, etc.
  • When energizing large banks, __________ current can be considerable and may negatively affect customer service if not performed properly.
  • How do you compute transformer impedance in per unit on a chosen base?
  • Which term describes the maximum fault current a circuit breaker can interrupt without damage at a given voltage?
  • In a transformer with no moving parts, the losses arise from field excitation and the resistance of what component?
  • Which coil shape is identified as producing a stronger magnetic field compared to a flat coil?
  • The size of an electric arc and destruction it can cause are directly proportional to the amount of ________ being interrupted.
  • What is the primary purpose of the short-term outages used during fault conditions?
  • Which statement best describes how an impedance relay decides to trip?
  • Distribution transformers provide power to which customers?
  • What is the primary purpose of insulating the laminated sheets in transformer cores?
  • Which device may share winding and potentially have no electrical isolation between circuits?
  • Portions of the mechanical linkages connected to movable contacts must be constructed of __________ materials to prevent energizing the CB components such as the tank and controls.
  • What does it mean for a circuit breaker to operate in 3-pole mode?
  • Which component provides a visual indication that a circuit is disconnected from energy sources?
  • __________ are provided as a method of visually confirming that a circuit has been 'disconnected' from specified sources of electrical energy.
  • ________ circuits use auxiliary devices that direct the operation of the CB.
  • After a fault occurs, operators re-establish service by routing current to circuits that are not ______.
  • Fault currents are described as currents that, if not controlled, can cause widespread outages.
  • Which banks step down transmission system voltage from 138 kV or 230 kV to 34.5 kV?
  • During surface faults, porcelain fragmentation is observed on the surface of a ______ or insulator.
  • Transformers and voltage regulators must be energized and de-energized using __________.
  • Which formula correctly expresses the symmetrical three-phase fault current in terms of line-to-line voltage and equivalent impedance?
  • What is the typical maintenance action for the operating mechanism of a circuit breaker?
  • ______ are hook-stick operated and gang-operated.
  • What is the purpose of a mechanical interlock between a circuit breaker and a disconnect switch?
  • __________ are designed to open, close, energize, de-energize, and interrupt normal and abnormal values of current flow in electrical circuits.
  • What is the difference between an on-load tap changer (OLTC) and an off-load tap changer?
  • How does a tap changer affect transformer voltage regulation under varying load?
  • __________ are usually made of insulating porcelain.
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy